Rokopol® RF152V is a propoxylated Mannich base, reactive multifunctional polyether aromatic polyol for polyurethane (PUR) rigid and semi-rigid foam production in reaction with isocyanate. It exists in the form of orange to brown colour, without antioxidants. It retains high viscosity 5,000-10,000 mPas at temp. 25°C, high functionality of f~4.5 and high hydroxyl value of 410–450 mgKOH/g.
Rokopol® RF152V is reactive polyol, product dedicated to production of polyurethane PUR systems with medium and higher viscosity and very good mechanical properties of rigid PUR foam. Product is recommended in particular as polyether additive for production of closed-cell systems of spray foam PUR. Mannich polyols demonstrate very high miscibility with typical polyols for application of rigid foam, i.e. sorbitol, sucrose and with most polyester polyols. This ensures big freedom in designing new polyurethane systems of rigid PUR foam.
Main advantages of application of Rokopol RF152V:
possibility of reducing concentration of the catalyst (important in particular with application of new physical foaming agents which have adverse effects on catalytic systems),
improved mechanical properties of the rigid foam core,
aromatic chemical structure improves flammability properties of the rigid PUR foam,
homogeneous and fine cell structure of the rigid PUR foam,
very good miscibility with hydrophobic n-pentane despite its unique hydrophilic nature.
Most popular PUR applications for polyol Rokopol® RF152V:
insulations of wires, cables, pipelines,
sandwich panels, insulation boards,
casting foams and spray foams,
systems for production of sandwich panels using continuous method,
Polyether polyol based on Mannich base and amine, Mannich, Mannich base, alkoxylated Mannich base.
Manufacturer: PCC Rokita SA
PCC Rokita SA is one of the largest chemical companies in Poland as well as Central and Eastern Europe. Its activity includes the production of chloroalkali, polyether polyols, polyalkylene glycols and phosphorus derivatives.
All the above information related to the product are provided according to the best knowledge of the manufacturer and published in good faith. However, the manufacturer does not guarantee the information and contents of this document are complete and accurate, and shall not be liable for the results of using them. The user is obliged to verify and confirm the information and contents of this documentation on his/her own. The manufacturer reserves the right to change the content of this document at any time without stating reasons of such changes.